High-Quality Oil Eliminates Overheating Shutdowns

Monolec® Vacuum Pump Sealing Oil (6322) is a high-quality lubricant designed to increase equipment life and improve performance of liquid ring vacuum pumps. Formulated using highly refined mineral oils and optimized for severe service conditions, it offers rust and corrosion protection, oxidation stability and water-separating characteristics. It also contains Monolec, LE's proprietary wear-reducing additive that provides additional protectionmore
Unit of Measure

Benefits and Recommendations

Available Container Size

275 Gal Disposable

Buy this LE Product!

Don't See Pricing? Register Today!"

Beneficial Qualities

High Temperature Performance
  • Reduces operating temperatures
  • Maintains performance under high-heat conditions
  • Minimizes viscosity changes as temperature fluctuates
  • Eliminates overheating and automatic shutdowns
Rust, Corrosion and Water Resistance
  • Mitigates varnish
  • Exhibits long-term oxidation and thermal stability
  • Resists formation of rust, corrosion and deposits
  • Separates rapidly from water
  • Provides exceptional resistance to moisture
Long-Lasting Protection
  • Minimizes wear under high-load conditions
  • Prolongs equipment life
  • Reduces maintenance costs
  • Provides long oil service life
  • Extends oil drain intervals

Performance Requirements Met or Exceeded

USDA H2

Typical Applications

Closed loop liquid ring vacuum pumps

Physical Characteristics

Color

Red

ISO VG

22

Performance Test Results

Relative Density @ 60ºF/60ºF, ASTM D1298

0.85

Viscosity @ 100°C, cSt, ASTM D445

4.48

Viscosity @ 40°C, cSt, ASTM D445

22.86

Viscosity Index ASTM D2270

113

Flash Point ºC (ºF), (COC), ASTM D92

208 (406)

Pour Point °C (°F), ASTM D97

-24 (-11)

Rust Test 4 hrs @ 60°C, DI H20, ASTM D665A

Pass

Rust Test 4 hrs @ 60ºC, Sea H2O, ASTM D665B

Pass

Copper Corrosion 3 hrs @ 100ºC, ASTM D130

1b

Oxidation by RPVOT @ 150ºC, minutes, ASTM D2272

750

Foaming Characteristics @ 24°C/93.5°C/24°C, 3 sequences, tendency/stability-time to break, ml/ml-sec, ASTM D892

20/0-9; 10/0-4; 20/0-4