Heavy-Duty Synthetic Grease Provides Extreme Protection

5100 is the Aerosol version of "Pyroshield 5182 Grease"


Pyroshield Syn Open Gear Grease is a heavy-duty synthetic lubricant developed for large unshrouded open gears in the mining, mineral processing and cement industries, and for other severe service applications that require a lubricant with superior wear protection, exceptional load-carrying ability, outstanding tackiness and ease of application at various temperatures. It also works well for applications in which gears experience high point-of-contact temperatures of 327ºC (620ºF) and above.

A product of advanced lubricant technology providing boundary lubrication, unmatched performance and versatility, Pyroshield Syn Open Gear Grease is formulated with high-viscosity 100 percent synthetic base oil, a non-melting thickening system and LE's proprietary heat stable additives. It contains a synergistic mix of Almasol®, LE's exclusive wear-reducing additive, and a unique combination of extreme pressure additives.

Pyroshield®, Almasol® and Duolec® are registered trademarks of Lubrication Engineers, Inc.

Lubrication Engineers operates under an ISO 9001 Certified Quality System.
Unit of Measure

Benefits and Recommendations

Available Container Size

N/A Case 12 Aerosols

Buy this LE Product!

N/A Don't See Pricing? Register Today!

Beneficial Qualities

N/A
  • NLGI 2 applied, 2 in use (5182)
  • NLGI 0 applied, 2 in use (5180)
  • Aerosol as applied, 2 in use (5100)

Available Grades

N/A
  • NLGI 2 applied, 2 in use (5182)
  • NLGI 0 applied, 2 in use (5180)
  • Aerosol as applied, 2 in use (5100)

Proprietary Additive

N/A Conclusion

The graph clearly shows the outstanding preventive wear performance that Pyroshield Syn Open Gear Grease provides as compared to competitive products. Load Wear Index (LWI) is a measure of lubricant's ability to carry a load and minimize wear. The higher the value, the better the lubricant does in preventing wear.

LE Modified Timken Test

N/A Conclusion

The results of the comparative product testing demonstrate the outstanding load-carrying capacity of Pyroshield Syn Open Gear Grease. It outperformed every competitive product that was tested. Pyroshield had a narrower wear scar and a lower block temperature than all the other lubricants. The test blocks of the competitive products experienced higher temperatures as a result of friction due to poor lubrication. The difference is easily visible in the amount of discoloration of the test blocks.
a1297.jpg

Pyroshield vs Competitive Open Gear Lubricants LWI

N/A Conclusion

The graph clearly shows the outstanding preventive wear performance that Pyroshield Syn Open Gear Grease provides as compared to competitive products. Load Wear Index (LWI) is a measure of lubricant's ability to carry a load and minimize wear. The higher the value, the better the lubricant does in preventing wear.
a1375.jpg

Recommendations

N/A
  • Various applications in the mining and mineral processing industry
  • Open gears and slides
  • Ball mill open gears
  • Kiln open gears
  • Bar screens
  • Dipper sticks
  • Circle rails

Typical Applications

N/A
  • Various applications in the mining and mineral processing industry
  • Open gears and slides
  • Ball mill open gears
  • Kiln open gears
  • Bar screens
  • Dipper sticks
  • Circle rails

Asset Reliability Solutions

N/A Reliability Solution Products

Customer Testimonials

N/A 5100 City of Moore

Physical Characteristics - Typical

Thickener Type

N/A Bentone

Texture

N/A Smooth/Tacky

Color

N/A Purple

NLGI Grade as Applied

N/A 2

NLGI Grade in Service

N/A 2

Performance Test Results

Worked 60 Penetration ASTM D217

N/A 275

Worked 10K Penetration ASTM D217

N/A +14

Worked 100K Penetration ASTM D217

N/A +28

Dropping Point ºC(ºF), ASTM D2265

N/A Non-melt

Flash Point ºC (ºF), ASTM D92

N/A 224 (435)

Viscosity @ 100°C, cSt, ASTM D445

N/A 690

Viscosity @ 40°C, cSt, ASTM D445

N/A 26,180

Pour Point °C (°F), ASTM D97

N/A 3 (37)

Oxidation drop in psi @ 100 hrs, ASTM D942

N/A 3

Corrosion Prevention DI H2O, ASTM D1743

N/A Pass

Timken OK Load lbs, ASTM D2509

N/A 90

Four-Ball EP Weld Point kgf, ASTM D2596

N/A 500

Four-Ball EP Load Wear Index kgf, ASTM D2596

N/A 116

Four-Ball Wear @ 75ºC (167ºF), 1,200 rpm, 40 kgf, 60 minutes, mm wear, ASTM D2266

N/A 0.71

Water Spray-off % Loss, ASTM D4049

N/A <2.0

Copper Corrosion 24 hrs @ 100ºC, ASTM D4048

N/A 1b